Key Features of the BP NM MD Monoblock Series
The NBP BP NM MD series comprises industrial process burners in packaged (monoblock) execution or supplied as complete combustion systems, equipped with a heat-resistant refractory steel nozzle. Engineered for heat treatment furnaces and medium-to-high temperature industrial processes up to 900-950°C requiring reliability, rapid thermal cycling, and precise flame control, they cover capacities from 58 kW to 8.000 kW, offer a turndown ratio up to 1:15, continuous 24/7 operation, and full compliance with EN 746-2 and ISO 13577-2.

Simplified Integration and Reduced Maintenance
Choosing a BPN MD means relying on a system pre-assembled and tested in our factories in Spezzano di Fiorano. The robust structure and accessibility of the components are designed for heavy use in industrial environments, guaranteeing a long useful life and minimal maintenance interventions
Main Technical Specifications – BP NM MD Series
| Parameter | BP NM MD Specification |
|---|---|
| Thermal capacity range | 58 kW to 8.000 kW (model list available under Industrial Burner Heads) |
| Turndown ratio | Up to 1:15 |
| Flame type / exit velocity | Intensive medium/high-velocity flame, up to 120-150 m/s |
| Supported fuels | Natural Gas (NG), LPG, Hydrogen blends (H2 blends), Biomethane, SNG, SynGas |
| Air / gas ratio control | Modulating via mechanical linkage, Electronic Air/Gas Ratio Control, pneumatic ratio control, or pulse firing |
| Standard chamber backpressure | -10 mbar to +20 mbar |
| Maximum backpressure (Custom) | Up to +50 mbar |
| Maximum chamber temperature | Up to 900-950°C |
| Burner nozzle type | High-temperature heat-resistant steel nozzle (refractory alloy / AISI 310S or other alloys depending on the application) |
| Flame ignition | Direct spark ignition via ignition electrode in low-flow “soft start” mode or separate pilot burner |
| Flame detection | Ionization electrode or UV scanner (standard or continuous self-check) |
| Power modulation control signals | 4-20 mA, 0-10 V, open/close (3-point) command |
| Safety, standards & duty | Continuous operation (24/7), integrated valve proving system, EN 746-2 / ISO 13577-2 compliance; SIL safety and UL/FM/CSA/AGA options |
Standard Configurations & Customizations
- Control panel: compact version with onboard control panel as standard, or customized versions with separate control panel.
- Gas train: compact version with onboard gas train as standard, or customized versions with separate skid-mounted gas train.
- Burner nozzle & combustion head: customized versions available with various heat-resistant steel nozzle lengths to match different furnace wall thicknesses.
- High backpressure / negative draft operation: optional pneumatic flue-gas isolation valves from the combustion chamber to protect air train components, and supply pressure compensation systems for strong negative draft operation.